bd surepath collection vial 10ml

SurePath™ Collection Vial For use with the BD PrepStain

Fichier PDF

Materials Provided: Each package of BD SurePath Collection Vials contains: 25 or 500 BD SurePath Collection Vials with 10 mL of BD SurePath Preservative Fluid in each vial, Materials Required But Not Provided: Specimen collection device, Use either a broom-type sampling device with detachable head e,g,, Rovers® Cervex Brush® or a combination endocervical brush/ plastic spatula device with

BD SurePath™

The BD SurePath Pap test standardizes collection and ensures 100% of the collected sample is sent to the laboratory for processing, No diagnostic cells are discarded in the clinic, unlike those with “rinse and swish” systems, which on average can result in the loss of 37% of the collected sample during cell transfer, Learn more about the BD SurePath liquid-based Pap test BD SurePath liquid

Premarket Approval PMA

BD SUREPATH COLLECTION VIAL: Generic Name: processor, cervical cytology slide, automated: Applicant: BD Diagnostic Systems: 4025 stirrup creek drive: suite 400: durham, NC 27703: PMA Number: P970018: Supplement Number: S033: Date Received: 05/27/2016: Decision Date: 12/02/2016: Product Code: MKQ Advisory Committee: Pathology : Supplement Type: real-time process: Supplement …

Collection of the BD SurePath Pap Test with a broom device

Collection of the BD SurePath Pap Test with a broom device plus endocervical brush improves disease detection when compared to the broom device alone or the spatula plus endocervical brush combination Cytojournal, 2008 Feb 12;6:4, doi: 10,4103/1742-6413,45495, Authors Sharon Davis-Devine 1 , Sarah J Day, Amy Anderson, Ashley French, Darcy Madison-Henness, Naomi Mohar, Danielle Tansy, Adarsh

BD Onclarity™ HPV Assay 441990

Fichier PDF

The automated specimen preparation for the BD Onclarity HPV Assay is completed by the BD Pre-Warm Heater and the BD Viper™ /7 6\VWHP &HUYLFDO VSHFLPHQV FROOHFWHG LQ BD SurePath Collection Vials are extracted using BD FOX™ Extraction to release cellular DNA, The purified cellular DNA solution from each extracted specimen is transferred into

Cytology, SurePath Liquid-Based Pap Test

Specimens not collected in a SurePath collection kit, Expired preservative vials or vials received without the collection devices, Remarks, Stability, Ambient: 1 month; Refrigerated: 6 months; Frozen: Unacceptable, Reference Interval Normal range/expected values for a specific disease state, May also include abnormal ranges, Interpretive Data Background information for test, May include

BD Vacutainer™ Serum Tubes Capacity: 10mL; Tube size: 16

Description, In order to obtain serum samples from plastic tubes, the tube must have a coagulation activator added, As the plastic surface alone is insufficient to trigger the coagulation within an acceptable time, BD Vacutainer™ plastic serum tubes have silica particles added for this purpose,

Pap Smear for Cytology

Drop this contoured collection end into a vial of BD Surepath Preservative Fluid Collection Vial, Discard remaining device handle end of the spatula after each use, Place cap on vial until step 7 , Do not tighten cap , 5 Insert Cytobrush Plus GT device into the endocervix until only the bottom-most bristels are exposed at the os, Slowly rotate 1/4 to 1/2 turn in one direction, To reduce

192005: Gynecologic Pap Test, Liquid-based Preparation

Vial with PreservCyt® solution, ThinPrep®; SurePath® vial with CytoRich™ fixative, Collection, When using the ThinPrep® method, a gynecologic specimen is collected using a brush and plastic spatula as a cervical sampling system, Insert the brush into the endocervical canal until only the bottommost fibers are exposed, Slowly rotate the brush 1 / 4 to 1 / 2 turn in one direction, Do not

Recovery of DNA from BD SurePath cytology specimens and

Background: The AMPLICOR HPV Test has been validated for use with cervical cells collected in liquid-based preservative fluids, such as BD SurePath, It is currently recommended, however, that residual BD SurePath samples be stored at 4 degrees C prior to testing, Objectives: The aim of this study was to demonstrate that DNA isolated from SurePath cervical cytology specimens and stored at

Cervical screening: acceptable HPV tests

The BD Onclarity HPV test can be used with BD SurePath LBC sample from the original SurePath collection vial or Hologic ThinPrep LBC samples performed on the BD Viper LT …

Specimen Collection & Handling Instructions

Fichier PDF

o Liquid based collection vial with 10mL of cytology preservative o Cytology requisition o Polybag o Collection device two are available: 1, Pap Collection Broom Kit: Cervex-Brush® can sample the ectocervix and endocervix in one procedure, Note: The Cervex-Brush® is latex free, 2, Pap Brush/Spatula Collection Kit: Cytobrush™ & plastic spatula used to collect cells from the endocervix …